Bezmaksas piegāde pasūtījumiem virs 29€

  • check 10+ miljoni grāmatu
  • check Jaunumi katru dienu
  • check Vairāk nekā 1 miljons klientu mums uzticas
  • check Labas cenas un atlaides
  • check Piegāde visā Eiropā

Active Multispectral Bidirectional Distribution Function Measurement System - Mark J. Proctor

angļu valoda
2012-11-16
21,72 € 31,03 €

-30% ar kodu BOOKS

Piegādātāja noliktavā

Piegāde 10-16 darba dienu laikā

30 dienu atgriešanas politika

Today's highly technical battlefield environment dictates the need for a method of standoff target identification, which reduces risk to personnel and equipment. It is widely known that a given material will react differently to incident radiation than a dissimilar material. Certain materials may respond specularly while others tend to be diffuse. By measuring these responses, materials can be identified by ... Pilns apraksts

Jums varētu patikt arī

Aprašymas

Today's highly technical battlefield environment dictates the need for a method of standoff target identification, which reduces risk to personnel and equipment. It is widely known that a given material will react differently to incident radiation than a dissimilar material. Certain materials may respond specularly while others tend to be diffuse. By measuring these responses, materials can be identified by comparison with a known database. One method of building such a database for target recognition is by employing an active multispectral bidirectional reflectance distribution function (BRDF) measurement system. In the following text, such a system is developed and tested using a 1.5m and 2.0m tunable source. The system does not yet meet the desired 1.0m range; however, all major system components with exception to the source are well suited for this entire band. A detailed description of the components used is presented along with recommendations for further research. This particular BRDF measurement system implementation is the direct result of a previous attempt that encountered numerous errors. These errors were primarily attributable to nonlinearities, attenuation, and misalignments in the equipment utilized. Considerable effort was expended in order to reduce these anomalies mainly through component replacement. A comprehensive error analysis is presented for this system along with recommendations for a new system, which should reduce these abnormalities and improve data integrity and collection efficiency.

Vairāk informācijas

Autors Mark J. Proctor
Izdevējs Creative Media Partners, LLC
Izlaides gads 2012
Vāka tips Mīkstais vāks
EAN 9781288306909
Rakstiet savu atsauksmi
Jūs vērtējat: Active Multispectral Bidirectional Distribution Function Measurement System
Jūsu novērtējums:

Goodreads atsauksmes

21,72 € 31,03 €